Oil Temperature Control Units(High)/High-Temperature Oil Temperature Control Units (OTCUs) are specialized systems used to control and maintain high temperatures in oil-based applications. These units are crucial in various industries such as plastic processing, rubber manufacturing, food production, and chemical processing, where specific temperature management is essential for optimal performance.
Oil Temperature Control Units(High)/High-Temperature Oil Temperature Control Units (OTCUs)
◎ Reliable quality, few failures, stable operation.
◎ Simple operation,
◎ Multiple security protections
◎ Fault alarm and display
◎ Energy saving
◎ Long service life
◎ Temperature control 30-350°C
Oil Temperature Control Units(High)/High-Temperature Oil Temperature Control Units (OTCUs)
◎ Reliable quality, few failures, stable operation.
◎ Simple operation,
◎ Multiple security protections
◎ Fault alarm and display
◎ Energy saving
◎ Long service life
◎ Temperature control 30-350°C
| MODEL | Hytau®OTC-18H | Hytau®OTC-24H | Hytau®OTC-36H | |
| Temperature control range℃ | 30-350℃ | |||
| Temperature control accuracy℃ | ±1℃ | |||
| Power supply v | AC220 V/3Φ380V 50HZ/60HZ | |||
| Heat transfer medium | oil | |||
| Cooling mode | Indirect cooling (plate heat exchanger) | |||
| Heating energy KW | 18 | 24 | 36 | |
| Pump horsepower KW/HP | 0.75/1 | 1.5/2 | 1.5/2 | 2.25/3 |
L/MIN/KG/CM² | 60L/MIN 2.6KG/CM² | 145L/MIN 2.6KG/CM² | 145L/MIN 2.6KG/CM² | 200L/MIN 3.0KG/CM² |
120L/MIN 2.6KG/CM² | 180L/MIN 2.6KG/CM² | 180L/MIN 2.6KG/CM² | 225L/MIN 3.0KG/CM² | |
| Cooling water inlet pressure kg/cm KG/CM² | 2.6 | |||
| Make-up tank capacity (L) | 10 | 30 | ||
| Maximum power consumption KW | 13.5 | 19.5 | 26.25 | |
| Cooling water piping INCH | 1/2"PT | |||
| Circulating water piping INCH | 2 in 2 out /4 in 4 out to 3/8"PT or 1 in 1 out to 1"PT. | |||
| External dimension CM | 102X36X75 | 76X30X65 | 114X45X80 | 115X52X80 |
| Net weight KG | 110 | 150 | 150 | 200 |
Oil Temperature Control Units(High)/High-Temperature Oil Temperature Control Units (OTCUs)
Note: Due to technological innovation, the following data is for reference, all models are subject to
the actual product, pump and power can be selected according to customer requirements.
★ The oil type mold temperature machine is cooled indirectly by the cooler by the mold return oil.
★ Then the pump pressurized through the electric heating tube high-temperature heating and sent to the mold to meet the heating and constant temperature requirements.
★Imported hot water pump
- assure reliable quality stable running
★Heat transfer medium "Oil"
- direct cooling/indirect cooling with quality plate heat exchanger
★Taiwan BANGPU microcomputer controller
- Easy operation
- Complete safety protection
- Excellent fault indication system
- Power saving 35%
★ Advance Temperature Controller System
- temperature rises and falls fast
- the temperature control accurate and stable
- temperature tolerance ±1℃ (30-350℃ ).
★The control panel and the body are independent and isolated, which can assure good thermal insulation effect while extending the service life.
★Advanced processing design
- Stainless steel pipes are iIntegrated die-casting molding
- high pressure design
- explosion-proof design
- uniform heating,
- No leakage.
★Can be customized according requirement.